Configure A Havequick Input - Safran SecureSync 2400 User Manual

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

2.19  Configuring Input References
2.19.4

Configure a HaveQuick Input

A HaveQuick Input is available by default configuration through the Multi-I/O con-
nector (see
To configure the settings of the HAVE QUICK Input (also referred to as 'Refer-
ence'), go to its Edit window.
The Edit window allows the configuration of the following settings:
166
PPS Source
– choices are:
Message: The 1PPS on time point is extracted from the ASCII mes-
sage received.
1PPS
Pin: The origin of the 1PPS on-time-point is the 1PPS input con-
nector.
Baud
Rate: Determines the speed at which the input port will operate.
Data
Bits: Defines the number of Data Bits for the input output.
Parity: Configures the parity checking of the input port.
Stop
Bits: Defines the number of Stop Bits for the input port.
"Configurable Connectors" on
Format: Used to configure the formatting of the four available HAVE
QUICK outputs. The available output formats are as follows:
STANAG 4246 HQ I
STANAG 4246 HQ II
STANAG 4430 STM
STANAG 4430 Ext HQ
ICD-GPS-060A BCD
ICD-GPS-060A HQ
DOD-STD-1399 BCD
page 157).
CHAPTER
2
SecureSync 2400 User Manual Rev. 5.2

Advertisement

Table of Contents
loading

Table of Contents