Spectracom Epsilon Formats

5.4.13.1
Spectracom Epsilon TOD 1
This message corresponds to the TOD 1 format provided by EPSILON 2S/3S Ser-
ies products on RS232/422 ports.
The structure of this format is as follows:
<space>DD/MM/YYYY<space>HH:MM:SST(CR)(LF)
Length=23 bytes
Where:
<space>
DD
</>
MM
</>
YYYY
<space>
HH
:
MM
:
SS
T
(CR)
(LF)
SecureSync 2400 User Manual
separator
2-digit Day of month
separator
2-digit Month
separator
4-digit Year
separator
2-digit Hour
separator
2-digit Minutes
separator
2-digit Seconds
1-digit Timescale ( 'N' None, 'G' GPS, 'U' UTC, 'A' TAI, 'L' Local, 'M' Manual)
Carriage Return (ASCII Character 13 0x0D)
Line Feed (ASCII Character 10 0x0A)
Never been in sync
In sync with a reference
Out of sync, lost reference