APPENDIX
414
Output
Mode:
Direct Output Value
1PPS
1PPM
5MPPS/1PPS
Square Wave
Custom
Output
Value: Determines the output level (Low or High).
Re-
Initialize: Re- initializes square wave generation and aligns to
1PPS.
Signature
Control: Controls when the output will be present.  See
also:
"Signature Control" on
Edge: Used to determine if the on- time point of the output is the
Rising
or
Falling
edge of the signal.
Offset: Accounts for cable delays and other latencies [nanoseconds].
On-Time Point Pulse
pulse width of the first square wave pulse aligned to the 1PPS On-
Time Point.  This is only active when the alignment count is non-zero
[nanoseconds].
Pulse
Width: Pulse width of the output [nanoseconds].
Alignment
Count(s): The alignment counter determines how often
(in seconds) the square wave will be aligned back to the 1PPS.  Set-
ting zero will disable PPS alignment beyond the initial alignment.
Time
Alignment: (Enabled/Disabled) The time alignment enable
changes the function of the alignment counter to align the square
wave whenever the current time's seconds value is a multiple of the
alignment count. For example: If time alignment is enabled and align-
ment count is set to 15 seconds, the square wave will be aligned to the
1PPS when the seconds value on the time display equals 00, 15, 30,
45. The current Time Alignment range is from 0 to 3600 seconds.
page 183.
Width: The on-time point pulse width is the