Safran SecureSync 2400 User Manual page 506

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

APPENDIX
ASCII Time Code Output: Edit Window
To configure the ASCII Output, go to its Edit window. For instructions, see:
figuring Option Card Inputs/Outputs" on
The Web UI list entries for this card are: ASCII TIMECODE RS-232 and ASCII
TIMECODE RS-485.
490
to the front panel time display. See for more information on Local
Clocks.
Note:
The Timescale of the ASCII input (as configured in the
ASCII time source) must be set correctly, especially if other
input references are enabled. Failure to configure the Timescale
of the ASCII input correctly could result in time jumps occurring
in the System Time when input reference changes occur. These
time jumps could affect NTP and normal operation of the sys-
tem.
PPS Source
– choices are:
Message: The 1PPS on time point is extracted from the ASCII mes-
sage received.
1PPS
Pin: The origin of the 1PPS on-time-point is the 1PPS input con-
nector.
Baud
Rate: Determines the speed at which the input port will operate.
Data
Bits: Defines the number of Data Bits for the input output.
Parity: Configures the parity checking of the input port.
Stop
Bits: Defines the number of Stop Bits for the input port.
page 364.
SecureSync 2400 User Manual
"Con-

Advertisement

Table of Contents
loading

Table of Contents