Programmable Square Wave Out [1204-17] - Safran SecureSync 2400 User Manual

Hide thumbs Also See for SecureSync 2400:
Table of Contents

Advertisement

The Status window displays the following settings:
Signature
nature Control" on
Frequency: Indicates the configured frequency.
Phase: Displays the configured phase offset (e.g., to account for delays
caused by different cable lengths, or other latencies).
Lock: Shows, if the output frequency is locked to the SecureSync system-
disciplined oscillator.
5.2.3.6

Programmable Square Wave Out [1204-17]

The Model 1204- 17 Square Wave output Option Card provides four pro-
grammable square wave outputs for the SecureSync platform.
Inputs/Outputs: (4) Programmable square wave outputs
Signal Type and
Accuracy: ±50 ns (1σ)
Output Load
Rise Time to 90% of
SecureSync 2400 User Manual
Control: Controls when the output will be present. See also:
page 183.
Note:
Even if an output frequency status is LOCKED, it will not be
available at the output port, if the Signature Control for that port has
been DISABLED.
Connector: TTL (BNC)
Impedance: 50 Ω
Level: <10 ns