The Oscillator Status Panel
This panel provides comprehensive information on the current status of
SecureSync's timing state.
CHAPTER
4
SecureSync 2400 User Manual Rev. 5.2
1. Navigate to
MANAGEMENT > OTHER:
2. The
Oscillator Management
Oscillator
Type: Type of oscillator installed in the unit.
Disciplining
State: State of oscillator control and disciplining; indicates
whether or not the internal oscillator is currently being disciplined (steered
to an input reference). The states are: "Warm up", "Calibration", "Tracking
Setup", "Lock State", "Freerun", and "Fault".
1PPS Phase
Error: A tracking measurement [scaled time, in ns, or ms] of the
internal 1PPSs' phase error with respect to the selected input reference.
Long holdover periods or an input reference with excessive jitter will cause
the phase error to be high. The oscillator disciplining control will gradually
reduce the phase error over time. Alternatively, restarting the tracking
manually (see "Restart Tracking" under
page 252), or automatically via a pre-set Phase Error Limit, will quickly
reduce the phase error.
10 MHz Frequency
internal oscillator's frequency error, based on the phase accuracy error at
the beginning and end of a frequency measurement window (the length of
screen will display. It consists of two panels:
Error: An internal estimated calculation (in Hertz) of the
4.5  Quality Management
Disciplining.
"Configuring the Oscillator" on
313