3.4.4.8 Configure additional status

The front panel display allows the user to add up to 20 status in the MISC submenu.
To select the additional status, the user shall update the file "ipc_ihm.ini" that can be found in the folder
C:\Program Files\ZDS\LCD\
In this file, after the [MISC] section, the user shall add a line for each additional status that is expected to be
displayed, according to the following layout :
"StatusName"=("TableNumber","OffsetValue")"Type"
Where "TableNumber" is the STI100013 monitoring table from whom the status is included, "OffsetValue" is the
status offset in this table, and "Type" is the selected option for display.
Example:
On the proposed example, four additional status are added to the front panel display.
The first line allows to monitor the TTC Telemetry Unit A (TableNumber=0x1060) BitRate (OffsetValue =1) as a
float value.
The second line allows to monitor the TTC Telemetry Simulator #1 (TableNumber=0x1020) file number
(OffsetValue =6) as a integer value.
The third line allows to monitor the TTC Global Monitoring (TableNumber=0x1001) alarm status (OffsetValue =41)
as a hexadecimal value.
The last line allows to monitor the TTC Telemetry Unit A (TableNumber=0x1060) frame synchronizer status
(OffsetValue =49) with the transcription of the integer value into a string. In this example, the following transcription
is applied :
0 -> Search
1 -> Check
2 -> Locked
3 -> Flywheel
For a "List" option, each string is limited to 16 characters.
ZODIAC DATA SYSTEMS PROPRIETARY
[MISC]
Bitrate=(0x1060,1)FLOAT
File Number=(0x1020,6)INT
Alarm Misc=(0x1001,41)HEX
FrameSync=(0x1060,49)LIST:Search,Check,Locked,Flywheel
D102751
ZDS Ref :
Issue : 1
Rev.: 0
Date : July 11, 2019
Page 77