* d. Drum cleaning blade
Since the edge of the blade is vulnerable and can be easily damaged by factors such as the
adherence of paper dust. Replace the cleaning blade with new ones if poor images are printed
due to the damaged blade regardless of the number of output pages if which have been made.
* e. Separation fingers for drum
The paper jam may be caused if the tip of the separation finger is damaged or deformed. If there
is any problem with it, replace the finger with a new one regardless of the number of output
pages which have been made.
If any mark which was made by the finger appears on the printed image, clean the tip of the
finger.
Notes:
Wipe the tip of the finger lightly with a dry cloth trying not to deform it.
Do not leave the lint on the tip.
Apply patting powder to the tip of the fingers and drum surface after replacing or cleaning
them to reduce the load on the drum surface by the finger.
* f. Recovery blade
Replace the recovery blade regardless the number of output pages if the edge of the blade get
damaged.
When cleaning the inside of the cleaner unit, be careful of the following in order not to damage
the film attached on the toner recovery auger:
Do not use an air blower for cleaning (Use a vacuum cleaner).
When using a vacuum cleaner, be careful not to hit the nozzle of the vacuum cleaner to
the film.
When rotating the toner recovery auger, rotate it only in the same direction as that for
transporting toner.
* h. Transfer roller
If there is damage on the roller, replace it even if the replacement time has not come.
* i. Separation needle
When cleaning the separation needle, be careful not to bend the needlepoint or leave lint on the
needlepoint. If removing the dust is difficult, use brush to remove it.
* j. Transfer guide
If there is paper dust in the whole transfer unit including the transfer guide, wipe them with a dry
cloth. If the transfer guide is removed, clean the wall inside the unit.
* m, n. Main charger case/Needle electrode
Clean the main charger case with a cloth soaked in water and squeezed tightly, and then wipe
them with a dry cloth.
Clean the needle electrode only with the main charger cleaner.
Replace the needle electrode with a new one if it is damaged regardless of the number of output
pages which have been mode.
Notes:
Do not touch the needle electrode with your bare hand when attaching the needle electrode.
ES9160 MFP / ES9170 MFP
PREVENTIVE MAINTENANCE (PM)
© 2012 OKI DATA CORPORATION All rights reserved