Download Print this page

Oki ES9160 Maintenance Manual page 898

Advertisement

(9)
Turn ON the power while [0] button and [8] button are pressed simultaneously.
Updating starts and the LED on the download jig lights.
(10) When the update completes normally, the LED on the download jig starts blinking.
The LED on the download jig starts blinking approx. 20 seconds after the update started. It is
assumed that the update has failed if the LED does not start blinking even after 30 seconds have
elapsed. In this case, shut down the equipment and check the following items. Then clear the
problems and restart updating from the beginning.
Is the downloading jig connected properly?
Is the ROM attached to the downloading jig properly?
Have the update data been written correctly to the ROM on the jig?
Is the download jig or the equipment damaged?
Is the harness jig for board connection connected to connector (CN2) of the IF board and the
connector (CN4) of the finisher control PC board correctly?
(11) Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power
OFF using the main power switch.
(12) Remove the download jig and the harness jig for board connection from the finisher control PC
board.
Notes:
Be sure to secure the connection cable in the connector (CN4) of the IF board when the hole
punch unit (MJ-6103) has been installed.
(13) Install the board access cover.
(14) Remove the harness jig for board connection from the converter PC board.
(15) Install the converter PC board in the equipment.
(16) Install the rear cover of the equipment.
(17) Install the board access cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
P. 11-72 "11.6 Confirmation of the updated data"
ES9160 MFP / ES9170 MFP
FIRMWARE UPDATING
© 2012 OKI DATA CORPORATION All rights reserved
11 - 66