13. WIRE HARNESS CONNECTION DIAGRAMS
13.1 AC Wire Harness
HRNS-INLET-471
ACMAIN-L
A
INLET
B
(AC-IN)
ACMAIN-N
C
FG
1
Main power switch
2
3
4
Front cover
A
interlock switch
B
ADU interlock
B
switch
A
A
Damp heater
B
switch
A
B
HRNS-FUS-471-J
J560
HRNS-FUS-471
1
1
3
3
(Mini Uni-3pin)
J603
1
1
2
2
(Mini Uni-2pin)
CN431
4
3
2
1
LVPS
Fuse PC board
CN432
AC(N:SCN-DH)
1
AC(L:SCN-DH)
3
D-HTR-SCN
AC(N:DRM-DH)
D-HTR-DRM
4
AC(L:DRM-DH)
6
HRNS-D/H-471
CN433
1
D-HTR-CST
2
3
© 2012 OKI DATA CORPORATION All rights reserved
CN410
1
3
HRNS-MAIN-SW-471
CN411
AC-SW-IN(L)
3
AC-SW-OUT(L)
4
AC-SW-IN(N)
1
AC-SW-OUT(N)
2
HRNS-INTERLOCK-471
CN413
SW-OUT
1
Switching regulator
(LVPS)
SW-IN
3
CN414
SW-IN
3
SW-OUT
1
HRNS-FUS2-471-J
(For other models)
CN414
3
1
HRNS-FUS2-471
CN415
4
10
HRNS-PWR-LGC-471
Scanner
J40
J41
1
1
2
2
2
2
1
1
B
A
(Faston-#250)
(Faston-#250)
Scanner damp
heater thermostat
Drum
J562
1
1
2
2
B
A
(Faston-#250)
(Faston-#250)
Drum damp
heater thermostat
Fig.13-1
13 - 1
Fuser unit
CN412:
Fuser front
thermostat
J616
HTR_L
1
1
HTR1_N
2
2
HTR2_N
3
3
HTR3_N
4
4
HRNS-ACIN1-471(473)
VH-4pin
HRNS-ACIN2-471(473)
J45
J46
2
2
2
1
1
1
J42
2
1
HRNS-D/H-SCN-471
J568
HRNS-D/H-DRM-471
1
Drum damp heater
2
Optional for ODNA/OEL model, standard for other models
WIRE HARNESS CONNECTION DIAGRAMS
Fuser center
thermostat
Center heater lamp
Side heater lamp
Sub heater lamp
Scanner damp
heater (Right)
Scanner damp
heater (Left)
ES9160 MFP / ES9170 MFP