Download Print this page

Oki ES9160 Maintenance Manual page 982

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
Temperature drop
mode
setting during
printing(Center
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting during
printing(Center
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting during
printing(Center
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting during
printing(Center
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting during
printing(Side
thermistor)
Item
Subitem
Code
2140
2141
2142
2143
2190
2190
2190
2190
2191
Sub-
Default
Acceptable
Details
code
value
value
Fuser roller
Refer to
0~14
temperature during
content
printing(Side
s
thermistor/Plain
paper)
Fuser roller
Refer to
0~14
temperature during
content
printing(Side
s
thermistor/Thick
paper 1)
Fuser roller
Refer to
0~14
temperature during
content
printing(Side
s
thermistor/Thick
paper 2)
Fuser roller
Refer to
0~14
temperature during
content
printing(Side
s
thermistor/OHP film)
0
The first drop
Refer to
0~10
content
s
1
The second drop
2
0~10
2
The third drop
Refer to
0~10
content
s
3
The fourth drop
3
0~10
0
The first drop
Refer to
0~10
content
s
5
RAM
Contents
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
<Default value>
0
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
<Default value>
3
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-0.
<Default value>
4
Proce
Servic
dure
e UI
1
1
1
1
4
4
4
4
4

Advertisement