Oki ES9160 Maintenance Manual page 311

Advertisement

(5)
After a short time, the value B becomes stable and the display changes as follows.
(6)
Check if the value B is within the range of 234 to 246 (the output voltage range of the auto-toner
sensor is 2.34 V to 2.46 V).
(7)
If the value B is not within the range of 234 to 246, press the Up or Down button to adjust the
value manually.
Notes:
The relation between the button and the values A and B is as follows.
Button to be pressed
Up
Down
(8)
Press the [OK] or [INTERRUPT] button.
The drum, developer unit, etc. are stopped and the following is displayed.
[INTERRUPT]
(9)
Turn the power OFF.
(10) Install the toner cartridge.