Download Print this page

Oki ES9160 Maintenance Manual page 696

Advertisement

[2E14] Invalid parameter for USB storage
Classification
File sharing related error
Check item
Setting
[2E15] Exceeding maximum file capacity
Classification
File sharing related error
Check item
Setting
[2E30] Directory creation failure in USB storage
Classification
File sharing related error
Check item
Setting
[2E31] File creation failure in USB storage
Classification
File sharing related error
Check item
Setting
[2E32] File deletion failure in USB storage
Classification
File sharing related error
Check item
Setting
ES9160 MFP / ES9170 MFP
ERROR CODE AND TROUBLESHOOTING
The specified parameter is invalid.
If a template is being used, recreate the template. If the error
still occurs, turn the power OFF and then back ON. Perform
the job in error again.
There are too many files in the folder.
Delete some files in the folder. Perform the job in error again.
Creation of a directory failed.
Check if access privilege to the storage directory is writable.
Check if the server or local disk has sufficient space in its disk
capacity.
Creation of a file failed.
Check if access privilege to the storage directory is writable.
Check if the server or local disk has sufficient space in its disk
capacity.
Deletion of a file failed.
Turn the power OFF and then back ON. Perform the job in
error again.
If the error still occurs, check that there is no job, and format
the HDD with [5] + [C] + [START].
8 - 216
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures
Error item
Measures