Download Print this page

Oki ES9160 Maintenance Manual page 978

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
Temperature drop
mode
setting in ready status
(Center thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting in ready status
(Center thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting in ready status
(Center thermistor)
Item
Subitem
Code
2002
2009
2010
2028
2031
2040
2041
2041
2041
Sub-
Default
Acceptable
Details
code
value
value
Fuser unit error status
0
0~19
counter
Fuser roller
Refer to
0~12
temperature on
content
standby(Center
s
thermistor)
Fuser roller
Refer to
0~14
temperature during
content
printing(Center
s
thermistor/Plain
paper)
Fuser roller
Refer to
0~14
temperature during
content
printing(Center
s
thermistor/Thick
paper 3)
Pre-running time for
10
0~15
first printing(Thick
paper 3)
Drop control when
1
0~2
ready
0
The first drop
Refer to
0~10
content
s
1
The second drop
Refer to
0~10
content
s
2
The third drop
Refer to
0~10
content
s
1
RAM
Contents
M
0: No error 1: C410 (Once) 2: C410 (consecutively
occurred) 3: C460 4: C430 5: C440 6: C450 7: C440
8: C450 9: C440 10: C470 11: C470 12: C480 13:
C490 14: C470 15: C480 16: C490 17: C470 18:
C480 19: C490
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C
<Default value>
10
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
10
M
0: Invalid 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5
sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec.
11: 12 sec. 12: 14 sec. 13: 16 sec. 14: 18 sec. 15: 20
sec.
M
0: Invalid, 1:Valid, 2: Invalid in low temperature
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
Proce
Servic
dure
e UI
1
1
1
1
1
1
4
4
4

Advertisement