Download Print this page

Oki ES9160 Maintenance Manual page 980

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
mode
08
Setting
Process
Fuser
Temperature drop
mode
setting in ready status
(Side thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting in ready status
(Side thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting in ready status
(Side thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
setting in ready status
(Side thermistor)
Item
Subitem
Code
2075
2100
2101
2111
2120
2121
2121
2121
2121
Sub-
Default
Acceptable
Details
code
value
value
Pre-running operation
Refer to
0~6
cycle in ready status
content
and energy saving
s
mode (Times of heat
source ON)
Temperature setting
Refer to
0~14
of warming-up(Center
content
thermistor)
s
Temperature setting
Refer to
0~14
of warming-up(Side
content
thermistor)
s
Pre-running time
3
0~18
(Normal temperature)
Fuser roller
Refer to
0~12
temperature in ready
content
status(Side
s
thermistor)
0
The first drop
Refer to
0~10
content
s
1
The second drop
Refer to
0~10
content
s
2
The third drop
Refer to
0~10
content
s
3
The fourth drop
Refer to
0~10
content
s
3
RAM
Contents
M
0: Not controlled 1: 180 times 2: 360 times 3: 540
times 4: 720 times 5: 900 times 6: 1080 times
<Default value>
3
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
8
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
8
M
0: Disabled 1: 1 sec. 2: 2 sec. 3: 3 sec. 4: 4 sec. 5: 5
sec. 6: 6 sec. 7: 7 sec. 8: 8 sec. 9: 9 sec. 10: 10 sec.
11: 15 sec. 12: 20 sec. 13: 25 sec. 14: 30 sec. 15: 40
sec. 16: 50 sec. 17: 60 sec.
18: 150 sec.
M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5: 165°C
6: 170°C 7: 175°C 8: 180°C 9: 185°C 10: 190°C 11:
195°C 12: 200°C
<Default value>
10
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
M
This code is valid only when "20" is set to 08-2135.
Setting value x -5°C: from 0°C to -50°C
<Default value>
0
Proce
Servic
dure
e UI
1
1
1
1
1
4
4
4
4