[E480] Bridge unit opened during printing
Classification
Cover open jam
Proce
Check item
dure
1
Is the bridge unit open?
Is the bridge unit opening/
2
closing switch working?
(Perform the input check
in the test mode: 03-
[FAX]ON/[4]/[E]
3
Replacing board
Parts to be replaced
The bridge unit opening/closing
switch
LGC board
ES9160 MFP / ES9170 MFP
ERROR CODE AND TROUBLESHOOTING
Bridge unit open jam
Result
Yes
Remove the paper if there is any, then close
the unit.
No
Yes
No
Check if the connector of the bridge unit
opening/closing switch is disconnected.
Check if the connector CN302 / CN400 on
the LGC board is disconnected.
Check if the connector pins are
disconnected and the harnesses are open
circuited.
Check if the conductor pattern on the LGC
board is short circuited or open circuited.
Replace the bridge unit opening/closing
switch.
Replace the LGC board.
Replace the LGC board.
8 - 68
Error content
Measure
Remark
© 2012 OKI DATA CORPORATION All rights reserved