Download Print this page

Oki ES9160 Maintenance Manual page 876

Advertisement

(4)
Connect the download jig [1] to the jig connector (CN7) [8] on the finisher control PC board (FIN).
(5)
Turn the power ON with the main power switch while pressing the digital keys [0] and [8]
simultaneously.
Updating starts automatically and the LED on the download jig lights.
(6)
When the update is completed normally, the LED on the download jig starts blinking.
It is assumed that the update has failed if the LED does not start blinking even after 1 minute has
elapsed. In this case, shut down the equipment and check the following items.
Then clear the problems and restart the update from the beginning.
Is the downloading jig connected properly?
Is the ROM attached to the downloading jig properly?
Have the update data been written correctly to the ROM on the jig?
Is the download jig or the equipment damaged?
(7)
Turn OFF the power of the equipment and disconnect the download jig.
(8)
Install the download cover.
ES9160 MFP / ES9170 MFP
FIRMWARE UPDATING
[8]
Fig.11-39
© 2012 OKI DATA CORPORATION All rights reserved
11 - 44

Advertisement

loading

This manual is also suitable for:

Es9170