[EAF3] Gripper motor (M3) abnormality
Classification
Finisher jam
MJ-1033
Error
Gripper motor
Gripper arm home position sensor
Probable cause
Gripper motor (M3) abnormality
Gripper arm home position sensor
(S13) abnormality
Gripper arm exit sensor (S26)
abnormality
Faulty cables and connectors
Finisher control PC board (FIN)
abnormality
[EB30] Ready time-out jam
Classification
Finisher jam
Check item
Finisher
Parts to be replaced
IPC board
LGC board
Finisher controller PC board
[ED10] Skew adjustment motor (M1) home position detection abnormality
MJ-1101/MJ-1106 (when MJ-6103 is installed)
Classification
Finisher jam
© 2012 OKI DATA CORPORATION All rights reserved
Gripper arm motor home position detection error
Timing of detection
The turning OFF of the gripper arm home position sensor (S13) is not
detected in the specified time when the gripper arm is exited.
The turning ON of the gripper arm home position sensor (S13) is not
detected in the specified time when the gripper arm is returned to its
home position.
Checking and measures
Check if the electrical continuity of the coil is normal. If electricity is not
conducted, replace the motor.
Measure the voltage on pin CN10.8 on the finisher control PC board
(FIN). Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
does not fall within the range mentioned, replace the sensor.
Measure the voltage on TP27 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when not
shielded and within the range of 3.3V
does not fall within the range mentioned, replace the sensor.
If the error still occurs after replacing the motor, sensors and
connectors, exchange the finisher control PC board (FIN).
If the error still occurs after replacing the motor, sensors and
connectors, exchange the finisher control PC board (FIN).
Error content
Ready time-out jam
Measures
Check if the connector on the equipment is disconnected from the
finisher or the harnesses are open circuited. Correct if any.
Remark
Error content
Skew adjustment motor (M1) home position detection abnormality
8 - 105
Error content
±
5% when shielded. If the voltage
±