[C970] High-voltage transformer abnormality
Classification
Process related service call
Check Item
© 2012 OKI DATA CORPORATION All rights reserved
High-voltage transformer abnormality
1. Is the main charger installed securely?
2. Check if the spring of high-voltage supply contact point is
deformed.
3. Check if the needle electrode is broken or the main charger
grid is deformed.
4. Check if any foreign matters is on the needle electrode or
the main charger grid.
5. Check if the transfer roller and the separation needle are
installed securely.
6. Check if the transfer roller or the separation needle is
removed.
7. Check if there is any foreign matter attached on the transfer
roller or the separation needle.