4.7.17
Transfer unit
Notes:
When taking off the transfer unit, take off the process unit first to prevent the drum from light.
(1)
Take off the automatic duplexing unit.
P. 4-97 "4.11.1 Automatic Duplexing Unit
(ADU)"
(2)
Take off 2 brackets by removing 2 screws
each.
(3)
Disconnect 1 connector and then take off the
transfer unit.
4.7.18
Temperature/humidity sensor (S25)
(1)
Take off the rear cover.
P. 4-3 "4.1.6 Rear cover"
(2)
Disconnect 1 connector, remove 1 screw and
then take off the temperature/humidity
sensor.
© 2012 OKI DATA CORPORATION All rights reserved
Transfer unit
Fig. 4-174
Temperature/humidity sensor
Fig. 4-175
4 - 63
ES9160 MFP / ES9170 MFP
DISASSEMBLY AND REPLACEMENT