Probable cause
Faulty cables and connectors
Finisher control PC board
(FIN) abnormality
[EA50] Stapling jam
Classification
Paper jam in finisher section
MJ-1101
Check item
Finisher
Parts to be replaced
Finisher controller PC board
MJ-1032
Probable cause
Staple unit stapling start position
sensor (S17) abnormality
Staple unit staple empty sensor (S18)
abnormality
Faulty cables and connectors
Finisher control PC board (FIN)
abnormality
© 2012 OKI DATA CORPORATION All rights reserved
Checking and measures
Check if the electrical continuity between the connector terminals is normal.
If electricity is not conducted, replace the connector. (Finisher control PC
board (FIN): CN10, CN13)
If the error still occurs after replacing the switches, sensor and connector,
exchange the finisher control PC board (FIN).
Error content
Stapling jam
Check if there is any paper in the finisher or on the transport
path of the equipment or on the finishing tray. Remove it if there
is.
Is the jam cleared by taking off the staple cartridge from the
finisher and removing the staple sheet slid from the staple case?
Check if the actuator of the stapler interference sensor (S11)
moves smoothly.
Check if the connector CN2 on the finisher controller PC board is
disconnected from the stapler or the harnesses are open
circuited. Correct if any.
Check the harnesses in the stapler are disconnected or open
circuited. Correct if any.
Checking and measures
Measure the voltage on TP23 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when the sensor
is ON and within the range of 3.3V
±
5% when OFF. If the voltage does not fall within the range
mentioned, replace the staple unit.
Measure the voltage on TP24 on the finisher control PC board (FIN).
Then check that the measured voltage is 1V or lower when the sensor
is ON and within the range of 3.3V
±
5% when OFF. If the voltage does not fall within the range
mentioned, replace the staple unit.
Check if the electrical continuity between the connector terminals is
normal. If electricity is not conducted, replace the connectors. (Finisher
control PC board (FIN): CN17)
If the error still occurs after replacing the staple unit and the
connectors, exchange the finisher control PC board (FIN).