Download Print this page

Oki ES9160 Maintenance Manual page 204

Advertisement

4.10.3
Exit motor (M10)
(1)
Take off the paper exit unit.
(
P. 4-89 "4.10.2 Paper exit unit")
(2)
Remote 2 screws and take off the duct.
(3)
Release the harness from the harness
clamp.
Remove 1 screw and take off the motor
cover.
Notes:
When installing the motor cover, engage the
shaft of the motor cover and the bearing of
the gear.
(4)
Disconnect 1 connecter and take off the exit
motor and the heat sink.
Notes:
When installing the exit motor, make sure to
put on the timing belt.
ES9160 MFP / ES9170 MFP
DISASSEMBLY AND REPLACEMENT
Fig. 4-252
Gear
Fig. 4-253
Timing belt
Fig. 4-254
© 2012 OKI DATA CORPORATION All rights reserved
4 - 90
Duct
Harness clamp
Motor cover
Heat sink
Exit motor