Download Print this page

Oki ES9160 Maintenance Manual page 337

Advertisement

6.4.10
Judgment threshold adjustment for blank originals
The judgment level is adjusted for automatic identification of whether the original set is blank or not.
This adjustment is made when "OMIT BLANK PAGE" is selected on the control panel.
The adjustment value is simultaneously applied to all modes at PPC and scanning.
Code
Item to be adjusted
7618
Judgment threshold
adjustment for blank
originals
<Procedure>
The procedure is the same as that of
6.4.11
Surrounding void amount adjustment
The void amount around the network scanned image is adjusted.
In network scanning, since the void amount is very small in stored images, a shadow may appear
around the scanned image due to the subtle difference in the original sizes. This shadow can be
eliminated by adjusting the setting value.
The setting value is applied to all resolutions and color modes.
Code
Item to be adjusted
7489
Surrounding void
amount adjustment
<Procedure>
The procedure is the same as that of
© 2012 OKI DATA CORPORATION All rights reserved
Remarks
The larger the value is, the more an original
tends to be judged as a blank sheet.
Acceptable values: 0 to 255 (Default: 128)
P. 6-23 "6.4.2 Density adjustment".
When the value increases, the blank area around the scanned
image becomes wider, and the data on the image decrease.
Acceptable values: 0 to 255 (Default: 0)
The setting value "1" is equal to 1 dot with 600 dpi. (The value
"24" is equal to approx. 1 mm.)
P. 6-23 "6.4.2 Density adjustment".
6 - 29
< Adjustment Mode (05) >
< Adjustment Mode (05) >
Remark
ES9160 MFP / ES9170 MFP
SETTING / ADJUSTMENT