Connect the download jig [1] with the jig connector (CN16) on the Saddle control board.
(6)
Turn ON the power while pressing [0] and [8] simultaneously.
Updating starts and the LED on the download jig [1] lights.
(7)
When the update completes normally, the LED on the download jig [1] starts blinking.
The LED on the download jig starts blinking in approx. 8 seconds after the update started.
It is assumed that the update is failed if the LED does not start blinking even after 15 seconds
have elapsed.
In this case, turn the power OFF and check the following items.
Then, clear the problem and restart updating from the beginning.
Is the downloading jig connected properly?
Is the ROM attached to the downloading jig properly?
Have the update data been written correctly to the ROM on the jig?
Is the download jig or the equipment damaged?
(8)
Turn the power OFF and remove the download jig [1].
(9)
Install the saddle control PC board access cover.
(10) Set the saddle stitch unit back to the main unit and then close the upper front cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
P. 11-72 "11.6 Confirmation of the updated data"