[F106_5] ADI-HDD error: Authentication data transmission error
Classification
Other service call
Check Item
Setting
[F109_0] Key consistency error (Consistency check operation error)
Classification
Other service call
Check Item
Setting
ES9160 MFP / ES9170 MFP
ERROR CODE AND TROUBLESHOOTING
ADI-HDD error: The transmission of authentication data fails.
Reinstall the system ROM data (OS Data).
Reinstall the master data (HD Data).
•
In case this error occurred after returning SRAM data for
SRAM cloning:
Copy the ADI-HDD encryption key from FROM to
SRAM.
(1) Start the equipment in the 3C mode: [3] + [C] +
[POWER]
(2) The authentication menu is displayed. Press [OK].
(Not required in the default setting)
(3) Select "5. Key Backup Restore" and then press the
[START] button.
(4) Select "6. ADIKey FROM to SRAM" and then press
the [START] button.
(5) After the restoring of the encryption key has
completed, "Operation Complete" is displayed.
(6) After the operation has completed, shut down the
equipment by pressing the [POWER] button.
Key consistency error - Key consistency check on each key
data fails.
Reboot the equipment.
If it cannot be recovered, reinstall the software in the following
procedure.
(1)
Install the OS data.
P. 11-9 "11.2.1 Master data/System ROM/Engine
ROM/Scanner ROM / RADF ROM"
(2)
Reinstall the master data and application program.
P. 9-9 "9.2.3 Precautions and procedures when
replacing the HDD"
[E] Replace / Format HDD (Step (3) and later in [E]
Replace / Format HDD)