6.8
Adjustment of High-Voltage Transformer
When replacing the high-voltage transformer, you must check each output adjustment of the main
charger bias, developer bias, transfer bias, transfer cleaning bias (positive), transfer cleaning bias
(negative) and separation bias.
6.8.1
Adjustment
[ 1 ] Preparation
Items to check
Developer Bias
Process Unit
Take the process unit out of the equipment, an then install the high-voltage transformer
jig to the unit.
High-Voltage
Install the high-voltage transformer jig in the equipment.
Transformer Jig
Digital
(+) terminal
Connect with the
Tester
black cable (thick
line) of the high-
voltage
transformer jig.
(–) terminal
Function
switch
Full-scale
(range)
Remarks
Use a digital tester with an input resistance of 10 MΩ (RMS value) or higher.
How to turn ON
Attach the door switch jig and start with the adjustment mode [05] while the front cover
the power
opened.
Note
Connection for
developer bias
adjustment"
© 2012 OKI DATA CORPORATION All rights reserved
Main Charger
Notes:
Connect the green cable of the high-voltage transformer jig to ground on the
equipment frame.
P. 6-44 "[A] Installation of the high-voltage transformer jig".
Connect with the
red cable (thick
line) of the high-
voltage
transformer jig.
Connect with the black cable (thin line) of the high-voltage transformer jig.
1000 V
P. 6-46 "[B]
P. 6-46 "[C]
Connection for
main charger
adjustment"
6 - 43
Transfer Bias,
Transfer Cleaning
Bias(positive),
Transfer Cleaning
Bias(negative)
Connect with the red
Connect with the
cable (thin line) of the
gray cable of the
high-voltage
high-voltage
transformer jig.
transformer jig.
DC
20 V
P. 6-47 "[D]
Connection the transfer
Connection for
bias, transfer cleaning
separation
bias(positive) and
charger
transfer cleaning
adjustment"
bias(negative)
adjustment"
ES9160 MFP / ES9170 MFP
SETTING / ADJUSTMENT
Separation
Charger
P. 6-47 "[E]