Error number
Time out
R01
(When the download is requested)
Time out
R02
(When the download is written)
Time out
R03
(When the download is finished)
Deletion error
R05
(When the download is written)
Writing error
R06
(When the download is written)
Reception status code abnormality
R08
(When the download is requested)
Reception status code abnormality
R09
(When the download is written)
Reception status code abnormality
R10
(When the download is finished)
RADF Uninstallation
R21
RADF Firmware model mismatch
R23
R00
Other error
(9)
Press the [ON/OFF] button to shut down the equipment, and then remove the USB media.
Notes:
When the equipment has been shut down normally, the LCD screen and LEDs (green and red)
go OFF. When OS data have been updated and the equipment has been shut down immediately after the
update, the LEDs (green and red) may not go OFF even if the LCD screen goes OFF. This indicates that the
equipment is not shut down normally. Press the [ON/OFF] button on the control
panel for more than 5 seconds, and then turn the main power switch OFF. Then remove the USB media.
(10) Perform the initialization of the updating data.
Press the [ON/OFF] button while simultaneously holding down the [0] and [8] buttons.
Key in "9030", and then press the [START] button.
Press the [INITIALIZE] button.
[B] Confirmation of the updated data
After the updating is completed, check each data version in the Setting Mode (08) to confirm that the
data were overwritten properly.
P. 11-72 "11.6 Confirmation of the updated data"
© 2012 OKI DATA CORPORATION All rights reserved
RADF update Error
Error message
11 - 15
Error content
Communication timeout
(When the download is requested)
Communication timeout
(When the download is written)
Communication timeout
(When the download is finished)
Deletion error
(When the download is written)
Writing error
(When the download is written)
Reception status code abnormality
(When the download is requested)
Reception status code abnormality
(When the download is written)
Reception status code abnormality
(When the download is finished)
RADF not installed
RADF ROM for different model
data connected
Other error
ES9160 MFP / ES9170 MFP