Download Print this page

Oki ES9160 Maintenance Manual page 984

Advertisement

Sub
05/08
Mode
Element
element
08
Setting
Process
Fuser
Temperature drop
mode
switching time setting
during printing on
thick paper(Center
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
switching time setting
during printing on
thick paper(Side
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
switching time setting
during printing on
thick paper(Side
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
switching time setting
during printing on
thick paper(Side
thermistor)
08
Setting
Process
Fuser
Temperature drop
mode
switching time setting
during printing on
thick paper(Side
thermistor)
08
Setting
Process
Fuser
Dropping temperature
mode
setting when printing
on thick paper
08
Setting
Process
Fuser
Dropping temperature
mode
setting when printing
on thick paper
08
Setting
Process
Fuser
Dropping temperature
mode
setting when printing
on thick paper
08
Setting
Process
Fuser
Dropping temperature
mode
setting when printing
on thick paper
08
Setting
Process
Fuser
Temperature drop
mode
setting during printing
on thick paper(Side
thermistor)
Item
Subitem
Code
2198
2199
2199
2199
2199
2200
2200
2200
2200
2201
Sub-
Default
Acceptable
Details
code
value
value
3
The fourth drop
75
0~200
0
The first drop
Refer to
0~200
content
s
1
The second drop
Refer to
0~200
content
s
2
The third drop
Refer to
0~200
content
s
3
The fourth drop
75
0~200
0
First drop
Refer to
0~10
content
s
1
Second drop
2
0~10
2
Third drop
Refer to
0~10
content
s
3
Fourth drop
3
0~10
0
The first drop
Refer to
0~10
content
s
7
RAM
Contents
M
Setting value x 5 seconds: from 0 to 1000 seconds
This code is valid only when "20" is set to 08-2214-1.
M
Setting value x 5 seconds: from 0 to 1000 seconds
This code is valid only when "20" is set to 08-2214-1.
<Default value>
5
M
Setting value x 5 seconds: from 0 to 1000 seconds
This code is valid only when "20" is set to 08-2214-1.
<Default value>
18
M
Setting value x 5 seconds: from 0 to 1000 seconds
This code is valid only when "20" is set to 08-2214-1.
<Default value>
24
M
Setting value x 5 seconds: from 0 to 1000 seconds
This code is valid only when "20" is set to 08-2214-1.
M
Setting value x 5°C: 0 to 50°C
This code is valid only when "20" is set to 08-2214-1.
<Default value>
0
M
Setting value x 5°C: 0 to 50°C
This code is valid only when "20" is set to 08-2214-1.
M
Setting value x 5°C: 0 to 50°C
This code is valid only when "20" is set to 08-2214-1.
<Default value>
3
M
Setting value x 5°C: 0 to 50°C
This code is valid only when "20" is set to 08-2214-1.
M
Setting value x -5°C: from 0°C to -50°C
This code is valid only when "20" is set to 08-2214-1
<Default value>
4
Proce
Servic
dure
e UI
4
4
4
4
4
4
4
4
4
4

Advertisement

loading

This manual is also suitable for:

Es9170