Download Print this page

Oki ES9160 Maintenance Manual page 326

Advertisement

[E] Image position adjustment of the secondary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3)
Press [FAX] -> [START] to make a copy at the mode of A3 (LD), 100% and the lower drawer
(Refer to *).
(4)
Measure the distance D from the leading edge of the paper to 10 mm of the copied image of the
ruler.
(5)
Check if the distance D is within the range of 10±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
(Key in a value (acceptable values: 90 to 166))
Press the [OK] or the [INTERRUPT] button (stored in memory).
("100% A" is displayed.)
* The larger the adjustment value is, the more the image is shifted to the trailing edge (0.13
mm/step).
ES9160 MFP / ES9170 MFP
SETTING / ADJUSTMENT
(Key in the code [3031])
Copied image of the ruler
10
20
D
Feeding direction
Fig.6-16
6 - 18
(Adjustment Mode)
[START]
30
40
© 2012 OKI DATA CORPORATION All rights reserved