Download Print this page

Toyota Camry Manual page 406

Hide thumbs Also See for Camry:

Advertisement

BODY ELECTRICAL SYSTEM
(e) Check that the current increases approximately 14.5
A or more when the window stops going down.
HINT: The circuit breaker opens some 4 – 40 seconds
after the window stops going down, so that check
must be made before the circuit breaker operates.
If operation is as specified, replace the master switch.
POWER WINDOW SWITCH INSPECTION
INSPECT POWER WINDOW SWITCH
Switch Continuity
Inspect the switch continuity between terminals.
Switch position
OFF
DOWN
If continuity is not as specified, replace the switch.
POWER WINDOW MOTOR INSPECTION
INSPECT POWER WINDOW MOTOR
Driver's Door Motor/ Motor Operation
(a) Connect the positive (+) lead from the battery to
terminal 1 and the negative (–) lead to terminal 2,
check that the motor turns clockwise.
(b) Reverse the polarity, check that the motor turns coun–
terclockwise.
If operation is not as specified, replace the motor.
Driver's Door Motor/ Circuit Breaker Operation
(a) Disconnect the connector from the master switch.
(b) Connect the positive (+) lead from the battery to
terminal 6 and the negative (–) lead to terminal 13 on
the wire harness side connector and raise the window
to full closed position.
(c) Continue to apply voltage, check that there is a circuit
breaker operation noise within approximately 4 to 40
seconds.
POWER WINDOW CONTROL SYSTEM
Tester connection to
terminal number
1–5
3–4
1–Z
3–4
1–2
4–5
BE–87
Specified value
Continuity
Continuity
Continuity

Advertisement

loading