INSPECTION PROCEDURE
Check pattern select switch.
Check connectors and harness between pattern select switch, PWR
indicator light and ECM (See page
Replace ECM.
AUTOMATIC TRANSAXLE
–
Disconnect pattern select switch connector.
Measure resistance between terminals 3 and6 of
pattern select switch connector when the select
switch is set to PWR and NORMAL positions.
TROUBLESHOOTING
Resistance
Pattern
0W (continuity)
PW R
NORM
1W
Replace pattern select switch.
IN–31
).
Repair or replace harness or connector.
AX1–101
(open)