AIR CONDITIONING SYSTEM
USE OF MANIFOLD GAUGE SET
MANIFOLD GAUGE SET INSTALLATION
1.
CONNECT CHARGING HOSES TO MANIFOLD
GAUGE SET
Tighten the nuts by hand.
CAUTION: Do not connect the wrong hoses.
2.
CONNECT QUICK CONNECTORS TO CHARGING
HOSES
Tighten the nuts by hand.
3.
CLOSE BOTH HAND VALVES OF MANIFOLD
GAUGE SET
4.
REMOVE CAPS FROM SERVICE VALVES ON RE–
FRIGERANT LINE
5.
CONNECT QUICK CONNECTORS TO SERVICE
VALVES
HINT: Push the quick connector onto the service
valve, then slide the sleeve of the quick connector
downward to lock it.
MANIFOLD GAUGE SET REMOVAL
1.
CLOSE BOTH HAND VALVES OF MANIFOLD
GAUGE SET
2.
DISCONNECT QUICK CONNECTORS FROM SER–
VICE VALVES ON REFRIGERANT LINE
HINT: Slide the sleeve of the quick connector upward
to unlock the connector and remove it from the ser–
vice valve.
3.
INSTALL CAPS TO SERVICE VALVES ON REFRIG–
ERANT LINE
USE OF MANIFOLD GAUGE SET
AC–21