AX1–38
AUTOMATIC TRANSAXLE
3. INSPECT KEY INTERLOCK SOLENOID
(a) Disconnect the solenoid connector.
(b) Using an ohmmeter, measure the resistance between
terminals.
Standard resistance:
12.5–16.50
(c) Apply the battery positive voltage between terminals.
Check that an operation noise can be heard from the
solenoid.
4. INSPECT SHIFT LOCK CONTROL SWITCH
Inspect that there is continuity between each termi–
nal.
Shift
Position
P position
(Release button is not pushed)
P position
(Release button is pushed)
R, N, D, 2, L Position
SHIFT LOCK SYSTEM
Terminal