Inspection; Ignition Housing - Single Parts Check; Ignition Housing - Check; Bearing Bushing - Check - Rotax 915 i A series Maintenance Manual

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

INSPECTION

IGNITION HOUSING — SINGLE PARTS
CHECK
Preparation
Clean all parts carefully. See Maintenance
Manual Line for the engine type 915 i A
Series. Chapter 05-00-00 section
Procedures.
IGNITION HOUSING — CHECK
Procedure
Step
1
Carry out visual inspection of sealing
surfaces.
2
Unscrew pressure sensor (oil). To do this,
see
Chapter 76-70-00 section Sensors
and
actuators.
Figure 2.21
Sealing surface
1
Step
Procedure
3
Blow compressed air through the lubrica-
tion bore and check it is clear.
4
Check that the pressed–in ball is sealed.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Figure 2.22
1
Lubrication bore
Step
Procedure
5
Check the sealing surface of the rubber
grommet for scratches (especially
lengthways).
Figure 2.23
Sealing surface for
1
rubber grommet
BEARING BUSHING — CHECK
NOTE
It is not possible to replace the bearing bushing,
as the inner bore and the lubrication bore are
machined after the bushing has been pressed.
If the bearing bushing is worn, the entire ignition
housing must be replaced.
2
Caulked ball
24–20–00
Page 13