Rotax 915 i A series Maintenance Manual page 407

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

ATTENTION
The ignition coils are arranged like the cylin-
ders (COIL_1, COIL_2, COIL_3, COIL_4). Igni-
tion coils 1 and 2 are the other way round from
ignition coils 2 and 4.
NOTE
The red cable is positive (+), the red cable with
the black dash is negative (-). Double ignition
coils are labelled + and -!
STRAIN RELIEF — CONNECTION
Step
Procedure
1
Attach strain reliefs to the wiring harness
with cable ties.
2
Fix clamps with Allen screws and wash-
ers. Apply LOCTITE 243 to screws.
Tightening torque 10 Nm (89 in. lb.)
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Figure 17.31
Figure 17.32
Cable clamp
1
3
Allen screw M6x16
5
Cable tie 142x3.2 mm
CONTROL UNIT (ECU) — CONNECTION
The sensors are connected and disconnected in the
same way. See
Chapter 76-50-00 section
FUEL PUMP — CONNECTION
The sensors are connected and disconnected in the
same way. See
Chapter 76-50-00 section
2
Washer 6.4
4
Cable tie 203x7.6 mm
Removal.
Removal.
76–50–00
Page 23
August 01 2018