Rotax 915 i A series Maintenance Manual page 420

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 18.13
Exhaust gas tempera-
1
ture sensor (EGT)
Step
Procedure
4
Use a size 17 open-ended spanner (or
similar tool) to detach the temperature
sensor from the exhaust pipe.
Figure 18.14: TYPICAL
Exhaust flange
1
Exhaust pipe
3
76–70–00
Page 12
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Locking plate
2
Exhaust gas tempera-
2
ture sensor
4
Sealing ring
OIL TEMPERATURE SENSOR (OTS) —
REMOVAL
Installation position: Crankcase
Step
Procedure
1
Cut open the cable ties.
2
Unplug the respective connector of the
wiring harness (main strand) from the cor-
responding temperature sensor.
See
Chapter 76-50-00 section Wiring har-
ness (main
strand).
3
Lift the latch and pull out the connector.
Figure 18.15
Oil temperature
1
sensor
Procedure
Step
4
Use an SW19 open-ended spanner part
no. 876130 (or a similar tool) to remove
the temperature sensor from the
crankcase.
5
Close the opening with the appropriate
protective plug.
CYLINDER HEAD TEMPERATURE
SENSOR (CTS) — REMOVAL
Installation position: Cylinder head (cylinder 4)
2
Cable ties
Effectivity: 915 i A Series