ECU ON WORKBENCH
ATTENTION
Do not open and close the ECU connectors
more than 20 times, otherwise it is required to
change the ECU and the wiring harness. If it is
possible it is recommended to perform the
software loading process as described in Sit-
uation 2 to save connection cycles. For a flaw-
less software loading procedure ensure that
the selected power supply is able to provide
constant voltage.
CONNECTION
Step
Procedure
1
Connect B.U.D.S. Aircraft Set with the
USB-Port of your computer.
If the device is connected and installed
the RED indicator light should light up.
2
Connect the B.U.D.S. Aircraft Set Sub-D
DE9 connector with the Sub-D DE9 sock-
et of the Y-cable.
3
Connect the Service Wiring Harness with
the LANE A1 and LANE B connectors of
the ECU.
ATTENTION
Please note labeling of the ECU and the Serv-
ice Wiring Harness.
Procedure
Step
4
Connect power adapter of Service Wiring
Harness with power supply (100-230
V~50/60 Hz, 500 mA).
5
Now the setup should be as shown in fol-
lowing figure.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Figure 15.9: Computer with ECU
Computer
1
Service Wiring
3
Harness
IDENTIFY CURRENT ECU
CONFIGURATION
Step
Procedure
1
Launch B.U.D.S. Aircraft by double click-
ing the desktop icon.
Alternatively B.U.D.S. Aircraft can also be
started through the start menu entry (e.g.
Start - Programs - BUDS - run BUDS).
2
B.U.D.S. Aircraft Set
4
ECU
76–10–00