INSTALLATION
Preparation
• Check all the wiring harness sections provided.
m WARNING
Non-compliance can result in serious injuries
or death! The wiring harness must not be
routed through areas or fastened to compo-
nents in which the maximum permissible tem-
perature of 120 °C (248 °F) can be exceeded
during engine operation.
ATTENTION
The wire connectors of the ECU must not be
opened and closed more than 20 times! This
must be shown on the device by a clearly visi-
ble label with a printed numerical sequence (1-
20) and by documentation conforming to self-
monitoring guidelines.
ATTENTION
Danger due to damage to the wiring harness!
For correct operation of the engine, it is neces-
sary for the wiring harness to be in full working
order and protected from scuffing, wear, tear-
ing, extreme bending radii and other types of
stress. Do not route the wiring harness in the
vicinity of belt drives or rollers without the use
of appropriate protective measures.
NOTE
Before connecting a connector, remove the pro-
tective covering which may be attached both to
the connector and to the connection socket.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
NOTE
If necessary, clean the pins of the connector
and coat them as follows: AMP/ECU connector
with a thin layer of Deoxit contact spray.
All the other connectors with a dielectric sili-
cone-based lubricant or an equivalent lubricant.
Procedure
Step
1
Lay the wiring harness correctly accord-
ing to the routing plan.
Figure 17.28
Wiring harness
1
FUSE BOX round
3
connectors
2
ECU connectors
Engine
4
76–50–00
Page 19
August 01 2018