Rotax 915 i A series Maintenance Manual page 195

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

NOTE
Remove the 2 insulating flanges between the in-
take manifold and the cylinder head.
Step
Procedure
6
Disconnect the spark plug connector and
remove the spark plugs. See
20-00 section
Figure 8.5
Temperature sensor
1
Spark plug connector
3
Procedure
Step
7
Release the attachment of the airbox to
the ignition housing.
8
Take off the spring type hose clip 25 using
spring clamp pliers part no. 877840.
9
Mark the coolant hoses and pull them off
of the coolant elbows (inlet). See
75-00-00 section Cooling
Effectivity: 915 i A Series
Edition 0/Rev. 0
MAINTENANCE MANUAL HEAVY
Chapter 74-
Distribution.
Hex./torx collar screw
2
M6x20
Insulating flange
4
Chapter
system.
BRP-Rotax
Figure 8.6
1
Airbox
3
Washer 6.4
Figure 8.7
1
Coolant elbow
3
Coolant hose
Step
Procedure
10
Loosen 2 Hex/Torx flange screws M6x20
along and remove the elbow flange.
2
Hex. nut M6
Spring type hose clip
2
25
4
Protection tube
72–30–00
Page 9
August 01 2018