INSTALLATION
Preparation
• Clean all parts carefully
• Remove protective coverings
OIL PRESSURE SENSOR (OPS) —
INSTALLATION
Step
Procedure
1
Clean the thread of the oil pressure
sensor.
2
Apply LOCTITE 243 to the thread of the
pressure sensor and use an 21 mm sock-
et wrench part no. 876075 (or a similar
tool) to tighten it. Tightening torque 15
Nm (133 in. lb.).
Figure 18.38
Oil pressure sensor
1
(OPS)
Step
Procedure
3
Plug the respective wiring harness con-
nector into the corresponding pressure
sensor. See
Chapter 76-50-00 section
Wiring harness (main
4
Attach cable ties (strain relief).
76–70–00
Page 26
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
strand).
Figure 18.39
Oil pressure sensor
1
(OPS)
BOOST PRESSURE SENSOR (BPS) —
INSTALLATION
Step
Procedure
1
Clean the thread of the boost pressure
sensor.
2
Tighten the pressure sensor with an 21
mm socket wrench part no. 876075 (or
similar tool). Tightening torque 10 Nm (89
in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding pressure
sensor. See
Chapter 76-50-00 section
Wiring harness (main
4
Make sure to put the connector latch to
the bottom.
2
Cable ties
strand).
Effectivity: 915 i A Series
Edition 0/Rev. 0