4
Tighten lock nut M5.
Tightening torque 3 Nm (27 in. lb.) and
then open counter-clockwise by 1.5 turns.
5
Slip on the full length of the black protec-
tion hoses.
Figure 2.33: TYPICAL
1
Distance sleeve
3
Washer 5.1/15.5/2.5
CONTROLLER CONNECTOR —
ASSEMBLY
Step
Procedure
1
Position the filler plug correctly. Position
wires correctly to connector pin labels,
using previously applied marks on wire
insulation.
2
Thread the lines through the insulator
(rubber).
3
Make the cable sleeves latch.
NOTE
Cables of generator B are thicker than cables of
generator A. Cables of generator B are yellow..
24–20–00
Page 18
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Disk springs
2
15x5.2x0.7
4
Lock nut M5
Figure 2.34
Filler plug
1
Connector receptacle
3
5
Cable sleeves
Step
Procedure
4
Install the orange lock.
NOTE
At malfunctions such as wire breakage and
faulty plugs, the particular damage can be
repaired.
Cable must be long enough after repair is made.
Repair of malfunctions with the tools mentioned
here must conform to the aircraft standards of
the respective country.
See also relevant Illustrated Parts Catalog
for the 915 i A Series engine type.
2
Insulator (rubber)
4
Marks
6
Latch
Effectivity: 915 i A Series
Edition 0/Rev. 0