Rotax 915 i A series Maintenance Manual page 395

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 17.7
1
Fusebox
Regulator connector
3
A
Regulator connector
5
B
Figure 17.8
1
Ground cable
Regulator connector
3
A
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Regulator LANE A
2
Regulator LANE B
4
EMS harness ground
6
cable
2
Regulator LANE A
Step
Procedure
2
Mark the regulator connector before
detaching.
3
Push in the tab on the top of the connec-
tor and at the same time pull the connec-
tor out of the connection socket.
Figure 17.9
Regulator connector
1
A
Figure 17.10
1
Connection socket
Procedure
Step
4
Loosen the two round connectors (la-
belled LANE A, LANE B) from fuse box.
Regulator connector B
2
Regulator connector
2
76–50–00