Rotax 915 i A series Maintenance Manual page 437

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 18.45
Manifold temperature
1
sensor (MATS)
3
Connector bracket
Step
Procedure
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See
section Wiring harness (main
4
Attach cable ties (strain relief).
Figure 18.46
Temperature sensor
1
(MATS)
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Sealing ring
2
Chapter 76-50-00
strand).
2
Cable ties
OIL TEMPERATURE SENSOR (OTS) —
INSTALLATION
Procedure
Step
1
Clean the thread of the oil temperature
sensor.
2
Apply LOCTITE 243 to the thread of OTS
and use an 19 mm socket wrench part
no. 876130 (or a similar tool) to tighten it.
Tightening torque 15 Nm (133 in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See
section Wiring harness (main
Figure 18.47
Oil temperature sen-
1
sor (OTS)
Step
Procedure
4
Attach cable ties.
Chapter 76-50-00
strand).
76–70–00
Page 29
August 01 2018

Advertisement