Step
Procedure
3
Disconnect the 2 RED/WHITE cable from
connection bolt B+. Remove the M5 lock
nut with washer. Wrench size: A/F 8. Re-
move the cable from connection bolt.
4
Disconnect the 2 BLACK cable from regu-
lator plate. Remove the 2 M4 lock nut with
washer. Wrench size: A/F 7 Remove the
cable from connection bolt.
5
Disconnect the 2 BLACK cable from con-
nection bolt B. Remove the M4 lock nut
with washer. Wrench size: A/F 7. Remove
the cable from connection bolt.
6
Disconnect the 2 BLACK cable from con-
nection bolt B-. Remove the M4 lock nut
with washer. Wrench size: A/F 7. Remove
the cable from connection bolt.
Figure 16.5
Regulator A
1
Connection bolt regu-
3
lator A
76–20–00
Page 6
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Regulator B
Connection bolt regula-
4
tor B
Figure 16.6
Lock nut M5 with
1
washer
Step
Procedure
7
Remove the regulator B. Remove the 2
M6 lock nut with washer. Wrench size: A/
F 10.
NOTE
Previous versions of the fuse box
may have M4 lock nuts on Regulator
B, new versions have M6 lock nuts.
Lock nut M4 with
2
washer