Rotax 915 i A series Maintenance Manual page 339

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Figure 14.25
Ignition housing
1
Pump shaft
3
Insertion jig
5
Step
Procedure
4
Install the ignition housing. See
24-20-00 section Internal
5
Push on the stainless compensating shim
and apply LOCTITE 243 to the thread of
the water pump shaft. Then fasten the im-
peller with the special tool part no.
877295 (with the crankshaft locked, see
relevant Maintenance Manual Line chap-
ter 12-20-00. Tightening torque 15 Nm
(133 in. lb.).
NOTE
Ensure that the impeller runs true. If there is no-
ticeable runout, this, and possibly also the pump
shaft, must be replaced.
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Oil seal
Rotary seal
4
Chapter
generator.
Figure 14.26: TYPICAL
Impeller
1
WATER PUMP HOUSING — ASSEMBLY
Step
Procedure
1
Lubricate the new bent socket with LOC-
TITE 243.
2
Screw the bent sockets at least 5 revolu-
tions into the water pump housing and po-
sition it.
NOTE
Usually, 3 bent sockets with a bend angle of 45°
and 1 bent sockets with a bend angle of 20° are
installed.
2
Washer 8.2/12.5/1.5
75–00–00
Page 21
August 01 2018

Advertisement

Table of Contents
loading