Rotax 915 i A series Maintenance Manual page 327

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

REMOVAL
Preparation
ATTENTION
Use appropriate protective coverings to pre-
vent the ingress of debris particles into all dis-
connected lines and connections.
• Switch the ignition key OFF
Drain coolant.
See Maintenance Manual Line for the en-
gine type 915 i A Series.
Drain the fuel.
See the Maintenance Manual Line for the
engine type 915 i A Series Chapter 12-20-
00 section Planned maintenance.
• Disconnect the form hose from outlet in accord-
ance with the aircraft manufacturer's specifications
NOTE
The assemblies and lines are only to be re-
moved if necessary and only as far as is
necessary!
Step
Procedure
1
Remove the fuel outlet and inlet hoses on
the fuel rail.
2
Unplug temperature sensor CTS. See
Chapter 76-70-00.
3
Remove temperature sensor EGT 1/3/4
from the cable bracket and unplug it. See
Chapter 76-70-00.
4
Unplug throttle position sensor TPS. See
Chapter
76-70-00..
5
Unscrew the resistance spark plug
connector.
See
Chapter
6
Remove the 1-ear clamp.
7
Remove the cable ties from the fuel pres-
sure regulator referance hose.
Effectivity: 915 i A Series
Edition 0/Rev. 0
MAINTENANCE MANUAL HEAVY
74-20-00.
BRP-Rotax
Step
Procedure
8
Loosen the Allen screw M6x16 of the fuel
line assy. with the lock washer.
9
Loosen the banjo bolt M12x1.5x24 from
cyl. 2/4 and 1/3 and remove the fuel line
assy.
10
Loosen 4 Allen screws on the intake
manifold (cyl. 2/4 and 1/3). See
73-10-00.
11
Remove the intake manifold (cyl. 2/4 and
1/3) with all its attached parts.
12
Remove the air intake hose from throttle
body.
Chapter
75–00–00
Page 9
August 01 2018

Advertisement

Table of Contents
loading

Table of Contents