INSTALLATION
MUFFLER ASSY. — INSTALLATION
Step
Procedure
1
Apply LOCTITE ANTI SEIZE. to the tur-
bine housing stud M8
2
Mount muffler assy. on studs of turbine
housing.
NOTE
Do not forget to install the turbocharg-
er bracket correctly.
Figure 20.13
Turbocharger
1
Turbocharger bracket
3
Step
Procedure
3
Apply LOCTITE ANTI SEIZE to screws.
Tighten the turbocharger with turbocharg-
er bracket using a reinforcement plate
and hex. screws.
Tightening torque 25 Nm (19 ft. lb.).
78–10–00
Page 10
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
2
Muffler assy.
4
Stud M8x19.5/13
Figure 20.14
Turbocharger
1
Reinforcement plate
3
Step
Procedure
4
Tighten muffler assy. with washers and
nuts M8 on turbine housing.
Tightening torque 25 Nm (19 ft. lb.).
Figure 20.15
Turbocharger
1
3
Washer
2
Hex. screws
Muffler assy.
2
4
Hex. nut