Figure 15.14
Step
Procedure
4
Disconnect the wiring connecting the
ECU with the computer.
• Disconnect power supply of the Service
Wiring Harness.
• Disconnect B.U.D.S. Aircraft Set
• Disconnect Service Wiring Harness
connectors
5
With the Windows Explorer navigate to
the created Log-File. This file can now be
copied and for example attached to an E-
mail or otherwise used.
76–10–00
Page 14
August 01 2018
BRP-Rotax
MAINTENANCE MANUAL HEAVY
SOFTWARE UPDATE
ATTENTION
Do not open and close the ECU connectors
more than 20 times, otherwise it is required to
change the ECU and the wiring harness. For a
flawless software flashing procedure ensure
that the selected power supply is able to pro-
vide constant power.
Preparation
Connect Computer with ECU and identify configura-
tion as described in the previous subsections in this
chapter.
Step
Procedure
1
Check the currently installed ECU Soft-
ware version and the set Engine type.
NOTE
The last three digits of the "Software
P/N" illustrate the currently installed
ECU Software version.