Figure 18.51
Connector (EGT)
1
KNOCK SENSOR (KNOCK) —
INSTALLATION
Procedure
Step
1
Clean the end face of the knock sensor.
2
Tighten the knock sensor. Tightening tor-
que 20 Nm (15 ft .lb.).
Figure 18.52
Connector (KNOCK)
1
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Locking plate
2
Binding head screw
2
M8x30
Step
Procedure
3
Plug the respective wiring harness con-
nector into the knock sensor.
4
Carefully push the connector (KNOCK) in
to the locking plate.
Figure 18.53
Connector (KNOCK)
1
3
Cable tie
Step
Procedure
5
Attach the cables of the knock sensor
with a cable tie .
Finishing work:
Follow the same procedure as removal when doing
this work. See Chapter 76-70-00 section Knock sen-
sor removal – preparation
CRANKSHAFT POSITION SENSOR
ASSY. (CPS_1/CPS_2) — INSTALLATION
ATTENTION
Ensure that the O-ring rests on the sensor.
NOTE
Oil the O-ring before installation.
2
Locking plate
76–70–00
Page 31