Rotax 915 i A series Maintenance Manual page 417

Hide thumbs Also See for 915 i A series:
Table of Contents

Advertisement

Step
Procedure
3
Pull the respective connector of the wiring
harness out of the corresponding pres-
sure sensor (MAPS_1/MAPS_2). See
Chapter 76-50-00 section Wiring harness
(main
strand).
4
Lift the latch and pull off.
5
Loosen the pressure sensor with an SW
21 open-ended spanner (or a similar tool)
and remove it.
6
Close the opening with the appropriate
protective plug.
Figure 18.6
1
Pressure sensor
OIL PRESSURE SENSOR (OPS) —
REMOVAL
Installation position: Ignition housing
Effectivity: 915 i A Series
Edition 0/Rev. 0
BRP-Rotax
MAINTENANCE MANUAL HEAVY
Step
Procedure
1
Cut open the cable ties on the oil pres-
sure sensor.
2
Pull the respective connector of the wiring
harness out of the corresponding pres-
sure sensor (OPS).
See
Chapter 76- 50-00 section Wiring
harness (main
3
Lift the latch and pull out the connector.
Figure 18.7
Oil pressure sensor
1
Step
Procedure
4
Loosen the oil pressure sensor with an
SW 19 open-ended spanner part no.
876130 (or a similar tool) and remove it.
5
Close the threaded bore with the appro-
priate protective covering.
AMBIENT AIR PRESSURE/
TEMPERATURE SENSOR (AAPTS) —
REMOVAL
Installation position: Aircraft frame
strand).
2
Cable ties
76–70–00
Page 9